<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-24 14-48-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
6.3 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 71 kHz 13969 24,1964
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,0 dBr 5,47 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 71 kHz MIN: 13 kHz % above 76 kHz: 24,1964 Acquired: 2025/02/24 14.47.12 Total samples: 13969 Equivalent time: 0:11:38 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,5 dBr MIN: 3,0 dBr AVE: 5,47 dBr % above 12,2 dBr: 0,0 Last value: 4,7 dBr (2025/02/24 14.47.12) 14.34 14.36 14.38 14.40 14.42 14.44 14.46 0 2 4 6 Pm [dBr]